Iimp 25kA Three phase VT Surge Arrester

  • Iimp 25kA Three phase VT Surge Arrester
  • Iimp 25kA Three phase VT Surge Arrester
  • Iimp 25kA Three phase VT Surge Arrester
  • Iimp 25kA Three phase VT Surge Arrester
  • Iimp 25kA Three phase VT Surge Arrester
  • Iimp 25kA Three phase VT Surge Arrester
Iimp 25kA Three phase VT Surge Arrester
  • Prosurge
  • China
  • Within 25 days
  • 10kpcs per month

Type1+2+3 surge arrester for low-voltage power supply system protection against surges at the boundaries from lightning protection zone 0B -3 and higher.

Surge protective device that Comply with IEC61643-11

VT technology, the best technology for power protection

Very low clamping level and high surge current capability Iimp 25kA 10/350 (High Iimp, low Up)

High TOV withstand, increased reliability for areas with unstable power network

No follow current + No leakage current + Intelligent distinguish Power frequency current and surge current to guarantee long service life


Part No.

B25VT/150(-S)/3PN100

B25VT/175(-S)/3PN100

B25VT/275(-S)/3PN100

B25VT/320(-S)/3PN100

B25VT/385(-S)/3PN100

In accordance with

IEC61643-11:2011; UL1449-4th

Category IEC/VDE

I + II + III/ B+C+D

Max. continuous operating voltage (V)

L-N(AC/DC)

150/200

175/225

275/350

320/420

385/505

N-PE(AC)

150

150

255

255

255

Nominal discharge current(8/20) In

L-N

25kA


N-PE

100kA

Max. discharge current(8/20) Imax

L-N

120kA


N-PE

200kA

Lightning impulse current(10/350) Iimp

L-N

25kA


N-PE

100kA

Open circuit voltage Uoc

20kV

Voltage protection level

L-N@In

<0.8kV

<0.8kV

<1.0kV

<1.2kV

<1.5kV


L-N@VPR

<0.5kV

<0.5kV

<0.6kV

<0.6kV

<0.8kV


N-PE@1.2/50

<1.0kV

<1.0kV

<1.5kV

<1.5kV

<1.5kV

Response time

L-N

≤100 ns


N-PE

≤100 ns

Follow current/Leakage current

L-N

No / No


N-PE

Ifi =100Arms @ 255Vac / No 

Backup fuse(only required if not already provided in mains)

315A gL/gG

Operating temperature range

- 40ºC ~ + 80ºC

Cross-section of connection wire

Single-strand 35mm2; multi-strand 25mm2

Mounting

35mm DIN-rail in accordance with EN 50022/DIN46277-3

Enclosure material

thermoplastic; extinguishing degree UL94 V-0

Degree of protection

IP20

Installation width

8 modules, DIN 43880

Thermal disconnector

Internal  red - failure

Remote alarm contact

Optional

Approvals, Certifications

CE

Additional data for Remote Alarm Contacts


Remote alarm contact type

Isolated Form C

Switching capability Un/In

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Max. Size of connecting wire

Max. 1.5mm2(or # 16AWG)


Prewired Multi-pole SPD

Part No.

 Pole

 Combination

 Power System

Ma x . Operating Voltage Uc

 Lightning Impulse

 Current (10/350μs) Iimp

 Voltage Protection        Level Up

 Diagram

B25VT/150-S/3P

3

3 x B25VT/150-S

Three phase 3W+G

150Vac

25kA

L-G: 0.8kV

2

B25VT/175-S/3P

3

3 x B25VT/175-S

Three phase 3W+G

175Vac

25kA

L-G: 0.8kV

2

B25VT/275-S/3P

3

3 x B25VT/275-S

Three phase 3W+G

275Vac

25kA

L-G: 1.0kV

2

B25VT/320-S/3P

3

3 x B25VT/320-S

Three phase 3W+G

320Vac

25kA

L-G: 1.2kV

2

B25VT/385-S/3P

3

3 x B25VT/385-S

Three phase 3W+G

385Vac

25kA

L-G: 1.5kV

2

B25VT/150-S/3PN100

4

3 x B25VT/150-S + G100/255NPE

Three phase 4W+G

150Vac

25kA / 100kA(NPE)

L-N: 0.8kV, N-PE: 1.5kV

1

B25VT/175-S/3PN100

4

3 x B25VT/175-S + G100/255NPE

Three phase 4W+G

175Vac

25kA / 100kA(NPE)

L-N: 0.8kV, N-PE: 1.5kV

1

B25VT/275-S/3PN100

4

3 x B25VT/275-S + G100/255NPE

Three phase 4W+G

275Vac

25kA / 100kA(NPE)

L-N: 1.0kV, N-PE: 1.5kV

1

B25VT/320-S/3PN100

4

3 x B25VT/320-S + G100/255NPE

Three phase 4W+G

320Vac

25kA / 100kA(NPE)

L-N: 1.2kV, N-PE: 1.5kV

1

B25VT/385-S/3PN100

4

3 x B25VT/385-S + G100/255NPE

Three phase 4W+G

385Vac

25kA / 100kA(NPE)

L-N: 1.5kV, N-PE: 1.5kV

1


Surge Diverter


Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right