TUV certified Type 1+2 AC Surge Protection Device

  • TUV certified Type 1+2 AC Surge Protection Device
  • TUV certified Type 1+2 AC Surge Protection Device
  • TUV certified Type 1+2 AC Surge Protection Device
  • TUV certified Type 1+2 AC Surge Protection Device
  • TUV certified Type 1+2 AC Surge Protection Device
  • TUV certified Type 1+2 AC Surge Protection Device
TUV certified Type 1+2 AC Surge Protection Device
  • Prosurge
  • China
  • 4-5 weeks
  • 30kpcs/month

TUV certified T1+ T2 SPD per IEC/EN 61643-11 standard and Use in TN/TT systems; Lightning current capacity up to 7.5 kA10/350μs(L-N), 12.5kA 10/350μs( (N-PE), Surge current capability up to 50kA 8/20μs;
Unique thermal disconnector design provides quick thermal response and secure disconnection, Low voltage protection level.
High short-circuit current rating up to 25kArms, suitable for application in most AC power system, Degradation failure indication and optional remote signal contact; Pluggable module for easy replacement without the need to remove system wiring.
Wide operating temperature -40ºC ~85ºC, 35mm DIN-rail mounting, Comply with UL1449 5th, IEEE C62.41,CSA C22.2 standards

The DT50/DS50 series are class I & class II (or T1+T2 ) SPD designed for low-voltage power system lightning current & surge protection, used at the boundaries from lightning protection zone 0B -2 and higher.

With built in PROSURGE high energy MOV and GDT, DT50 and DS50 series SPD ensures remarkable lightning current discharge capacity up to 7.5 kA 10/350μs(L-N), 12.5kA (N-PE) and high reliability. The unique design of thermal protection provides quick thermal response and secure disconnection.


Single Pole  L-N

V50/Uc-S

Part No.

V50/75(-S)

V50/150(-S)

V50/180(-S)

V50/275(-S)

V50/320(-S)

V50/350(-S)

V50/385 (-S)

V50/440(-S)

V50/480(-S)

V50/600(-S)

V50/750(-S)

In accordance with

IEC/EN 61643-11:2011; UL1449 5th

Category IEC/EU/VDE

I+ II /1+2/ B+C

Protection mode

L-N or L-PE or N-PE

Nominal Voltage (AC)  Un

60V

120V

120V

230V

230V

277V

277V

400V

400V

480V

600V

Power frequency

50/60Hz

Max. continuous operating voltage(AC) Uc

75V

150V

180V

275V

320V

350V

385V

440V

480V

600V

750V

Nominal discharge current(8/20)  In

20kA

Max. discharge current(8/20)  Imax

50kA

Lightning impulse current (10/350)  Iimp

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

6.0kA

4.5kA

4.5kA

3.5kA

Voltage protection level  Up

0.6kV

0.8kV

1.0kV

1.2kV

1.4kV

1.5kV

1.8kV

2.0kV

2.2kV

2.5kV

2.8kV

Response time  tA

≤25 ns

Temporary overvoltage TOV  UT

Withstand mode  

90V/5s

174V/5s

228V/5s

335V/5s

335V/5s

403V/5s

403V/5s

580V/5s

580V/5s

700V/5s

870V/5s

Follow current & interrupt rating  Ifi

No

Leakage current   Ipe

<0.1mA

Short-circuit current rating  Isscr

25kArms

Backup fuse(only required if not already provided in mains)

≤125A gL/gG

Operating temperature range

-40ºC ~ +85ºC

Altitude

-500m ~ +4000m

Cross-section of connection wire (max)

Single-strand 35mm2; multi-strand 25mm2

Mounting

35mm DIN-rail in accordance with EN 50022/DIN46277-3

Enclosure material

Thermoplastic; extinguishing degree UL94 V-0

Degree of protection

IP20

Installation width

1 module, DIN 43880

Thermal disconnector

Internal  Green – normal ; red - failure

Remote alarm contact

Optional

Approvals, Certifications

TUV, CE

Additional data for Remote Alarm Contacts

Remote alarm contact type

Isolated Form C

Switching capability Un/In

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Cross-section of remote signaling wire

Max. 1.5mm2(or # 16AWG)



Single Phase - 2 Poles  "2+0"

DS50/Uc-2V-S

Part No.

DS50/75-2V(-S)

DS50/150-2V(-S)

DS50/180-2V(-S)

DS50/275-2V(-S)

DS50/320-2V(-S)

DS50/350-2V(-S)

DS50/385-2V (-S)

DS50/440-2V(-S)

DS50/480-2V(-S)

DS50/600-2V(-S)

DS50/750-2V(-S)

In accordance with

IEC/EN 61643-11:2011; UL1449 5th

Category IEC/EU/VDE

I+ II /1+2/ B+C

Protection mode

L-PE ,N-PE

Nominal Voltage (AC)   Un

60V

120V

120V

230V

230V

277V

277V

400V

400V

480V

600V

Power frequency

50/60Hz

Max. continuous operating voltage(AC) Uc

75V

150V

180V

275V

320V

350V

385V

440V

480V

600V

750V

Nominal discharge current(8/20)   In

20kA

Max. discharge current(8/20)   Imax

50kA

Lightning impulse current (10/350)  Iimp

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

6.0kA

4.5kA

4.5kA

3.5kA

Voltage protection level  Up

0.6kV

0.8kV

1.0kV

1.2kV

1.4kV

1.5kV

1.8kV

2.0kV

2.2kV

2.5kV

2.8kV

Response time  tA

≤25 ns

Temporary overvoltage TOV  UT

Withstand mode  

90V/5s

174V/5s

228V/5s

335V/5s

335V/5s

403V/5s

403V/5s

580V/5s

580V/5s

700V/5s

870V/5s

Follow current & interrupt rating  Ifi

No

Leakage current  Ipe

<0.1mA

Short-circuit current rating  Isscr

25kArms

Backup fuse(only required if not already provided in mains)

≤125A gL/gG

Operating temperature range

-40ºC ~ +85ºC

Altitude

-500m ~ +4000m

Cross-section of connection wire (max)

Single-strand 35mm2; multi-strand 25mm2

Mounting

35mm DIN-rail in accordance with EN 50022/DIN46277-3

Enclosure material

Thermoplastic; extinguishing degree UL94 V-0

Degree of protection

IP20

Installation width

2 module, DIN 43880

Thermal disconnector

Internal  Green – normal ; red - failure

Remote alarm contact

Optional

Approvals, Certifications

TUV, CE

Additional data for Remote Alarm Contacts

Remote alarm contact type

Isolated Form C

Switching capability Un/In

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Cross-section of remote signaling wire

Max. 1.5mm2(or # 16AWG)



Single Phase - 2 Poles  "1+1"

DS50/Uc-(V+T)-S

Part No.

DS50/150-(V+T) (-S)

DS50/180-(V+T) (-S)

DS50/275-(V+T) (-S)

DS50/320-(V+T) (-S)

DS50/350-(V+T) (-S)

DS50/385-(V+T) (-S)

In accordance with

IEC/EN 61643-11:2011; UL1449 5th

Category IEC/EU/VDE

I+ II /1+2/ B+C

Protection mode

L-PE ,N-PE

Nominal Voltage (AC)  Un

120V

120V

230V

230V

277V

277V

Power frequency

50/60Hz

Max. continuous operating voltage(AC)  Uc

L-N

150V

180V

275V

320V

350V

385V

N-PE

150V

150V

255V

255V

255V

255V

Nominal discharge current(8/20)  In

20kA

Max. discharge current(8/20)  Imax

50kA

Lightning impulse current (10/350) Iimp

L-N

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

N-PE

12.5kA

12.5kA

12.5kA

12.5kA

12.5kA

12.5kA

Voltage protection level  Up

L-N

0.8kV

1.0kV

1.2kV

1.4kV

1.5kV

1.8kV

N-PE

1.5kV

1.5kV

1.5kV

1.5kV

1.5kV

1.5kV

Response time  tA

L-N

≤25 ns

N-PE

≤100 ns

Temporary overvoltage TOV  UT

Withstand mode  

L-N

174V/5s

228V/5s

335V/5s

335V/5s

403V/5s

403V/5s

N-PE

1200V/200ms

1200V/200ms

1200V/200ms

1200V/200ms

1200V/200ms

1200V/200ms

Follow current & interrupt rating  Ifi

N-PE

100A

Leakage current   Ipe

<0.1mA

Short-circuit current rating  Isscr

25kArms

Backup fuse(only required if not already provided in mains)

≤125A gL/gG

Operating temperature range

-40ºC ~ +85ºC

Altitude

-500m ~ +4000m

Cross-section of connection wire (max)

Single-strand 35mm2; multi-strand 25mm2

Mounting

35mm DIN-rail in accordance with EN 50022/DIN46277-3

Enclosure material

Thermoplastic; extinguishing degree UL94 V-0

Degree of protection

IP20

Installation width

2 module, DIN 43880

Thermal disconnector

Internal  Green – normal ; red - failure

Remote alarm contact

Optional

Approvals, Certifications

TUV, CE

Additional data for Remote Alarm Contacts

Remote alarm contact type

Isolated Form C

Switching capability Un/In

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Cross-section of remote signaling wire (max)

1.5mm2(or # 16AWG)




Three Phase - 3 Poles  "3+0"

DT50/Uc-3V-S

Part No.

DT50/75-3V(-S)

DT50/150-3V(-S)

DT50/180-3V(-S)

DT50/275-3V(-S)

DT50/320-3V(-S)

DT50/350-3V(-S)

DT50/385-3V (-S)

DT50/440-3V(-S)

DT50/480-3V(-S)

DT50/600-3V(-S)

DT50/750-3V(-S)

In accordance with

IEC/EN 61643-11:2011; UL1449 5th

Category IEC/EU/VDE

I+ II /1+2/ B+C

Protection mode

L-PE ,N-PE

Nominal Voltage (AC)  Un

60V

120V

120V

230V

230V

277V

277V

400V

400V

480V

600V

Power frequency

50/60Hz

Max. continuous operating voltage(AC) Uc

75V

150V

180V

275V

320V

350V

385V

440V

480V

600V

750V

Nominal discharge current(8/20)  In

20kA

Max. discharge current(8/20)  Imax

50kA

Lightning impulse current (10/350)  Iimp

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

6.0kA

4.5kA

4.5kA

3.5kA

Voltage protection level   Up

0.6kV

0.8kV

1.0kV

1.2kV

1.4kV

1.5kV

1.8kV

2.0kV

2.2kV

2.5 V

2.8kV

Response time  tA

≤25 ns

Temporary overvoltage TOV  UT

Withstand mode  

90V/5s

174V/5s

228V/5s

335V/5s

335V/5s

403V/5s

403V/5s

580V/5s

580V/5s

700V/5s

870V/5s

Follow current & interrupt rating  Ifi

No

Leakage current   Ipe

<0.1mA

Short-circuit current rating    Isscr

25kArms

Backup fuse(only required if not already provided in mains)

≤125A gL/gG

Operating temperature range

-40ºC ~ +85ºC

Altitude

-500m ~ +4000m

Cross-section of connection wire (max)

Single-strand 35mm2; multi-strand 25mm2

Mounting

35mm DIN-rail in accordance with EN 50022/DIN46277-3

Enclosure material

Thermoplastic; extinguishing degree UL94 V-0

Degree of protection

IP20

Installation width

3 module, DIN 43880

Thermal disconnector

Internal  Green – normal ; red - failure

Remote alarm contact

Optional

Approvals, Certifications

TUV, CE

Additional data for Remote Alarm Contacts

Remote alarm contact type

Isolated Form C

Switching capability Un/In

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Cross-section of remote signaling wire

Max. 1.5mm2(or # 16AWG)




Three Phase - 4 Poles  "4+0"

DT50/Uc-4V-S

Part No.

DT50/75-4V(-S)

DT50/150-4V(-S)

DT50/180-4V(-S)

DT50/275-4V(-S)

DT50/320-4V(-S)

DT50/350-4V(-S)

DT50/385-4V (-S)

DT50/440-4V(-S)

DT50/480-4V(-S)

DT50/600-4V(-S)

DT50/750-4V(-S)

In accordance with

IEC/EN 61643-11:2011; UL1449 5th

Category IEC/EU/VDE

I+ II /1+2/ B+C

Protection mode

L-PE ,N-PE

Nominal Voltage (AC)  Un

60V

120V

120V

230V

230V

277V

277V

400V

400V

480V

600V

Power frequency

50/60Hz

Max. continuous operating voltage(AC) Uc

75V

150V

180V

275V

320V

350V

385V

440V

480V

600V

750V

Nominal discharge current(8/20)  In

20kA

Max. discharge current(8/20)  Imax

50kA

Lightning impulse current (10/350)  Iimp

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

6.0kA

4.5kA

4.5kA

3.5kA

Voltage protection level  Up

0.6kV

0.8kV

1.0kV

1.2kV

1.4kV

1.5kV

1.8kV

2.0kV

2.2kV

2.5kV

2.8kV

Response time  tA

≤25 ns

Temporary overvoltage TOV  UT

Withstand mode  

90V/5s

174V/5s

228V/5s

335V/5s

335V/5s

403V/5s

403V/5s

580V/5s

580V/5s

700V/5s

870V/5s

Follow current & interrupt rating  Ifi

No

Leakage current  Ipe

<0.1mA

Short-circuit current rating  Isscr

25kArms

Backup fuse(only required if not already provided in mains)

≤125A gL/gG

Operating temperature range

-40ºC ~ +85ºC

Altitude

-500m ~ +4000m

Cross-section of connection wire (max)

Single-strand 35mm2; multi-strand 25mm2

Mounting

35mm DIN-rail in accordance with EN 50022/DIN46277-3

Enclosure material

Thermoplastic; extinguishing degree UL94 V-0

Degree of protection

IP20

Installation width

4 module, DIN 43880

Thermal disconnector

Internal  Green – normal ; red - failure

Remote alarm contact

Optional

Approvals, Certifications

TUV, CE

Additional data for Remote Alarm Contacts

Remote alarm contact type

Isolated Form C

Switching capability Un/In

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Cross-section of remote signaling wire

Max. 1.5mm2(or # 16AWG)



Three Phase - 4 Poles  "3+1" 

DT50/Uc-(3V+T)-S

Part No.

DT50/150-(3V+T) (-S)

DT50/180-(3V+T) (-S)

DT50/275-(3V+T) (-S)

DT50/320-(3V+T) (-S)

DT50/350-(3V+T) (-S)

DT50/385-(3V+T) (-S)

In accordance with

IEC/EN 61643-11:2011; UL1449 5th

Category IEC/EU/VDE

I+ II /1+2/ B+C

Protection mode

L-PE ,N-PE

Nominal Voltage (AC)  Un

120V/208V

120V/208V

230V/400V

230V/400V

277V/480V

277V/480V

Power frequency

50/60Hz

Max. continuous operating voltage(AC)  Uc

L-N

150V

180V

275V

320V

350V

385V

N-PE

150V

150V

255V

255V

255V

255V

Nominal discharge current(8/20)  In

20kA

Max. discharge current(8/20)  Imax

50kA

Lightning impulse current (10/350) Iimp

L-N

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

7.5kA

N-PE

12.5kA

12.5kA

12.5kA

12.5kA

12.5kA

12.5kA

Voltage protection level  Up

L-N

0.8kV

1.0kV

1.2kV

1.4kV

1.5kV

1.8kV

N-PE

1.5kV

1.5kV

1.5kV

1.5kV

1.5kV

1.5kV

Response time  tA

L-N

≤25 ns

N-PE

≤100 ns

Temporary overvoltage TOV  UT

Withstand mode  

L-N

174V/5s

228V/5s

335V/5s

335V/5s

403V/5s

403V/5s

N-PE

1200V/200ms

1200V/200ms

1200V/200ms

1200V/200ms

1200V/200ms

1200V/200ms

Follow current & interrupt rating  Ifi

N-PE

100A

Leakage current  Ipe

<0.1mA

Short-circuit current rating  Isscr

25kArms

Backup fuse(only required if not already provided in mains)

≤125A gL/gG

Operating temperature range

-40ºC ~ +85ºC

Altitude

-500m ~ +4000m

Cross-section of connection wire (max)

Single-strand 35mm2; multi-strand 25mm2

Mounting

35mm DIN-rail in accordance with EN 50022/DIN46277-3

Enclosure material

Thermoplastic; extinguishing degree UL94 V-0

Degree of protection

IP20

Installation width

4 module, DIN 43880

Thermal disconnector

Internal  Green – normal ; red - failure

Remote alarm contact

Optional

Approvals, Certifications

TUV, CE

Additional data for Remote Alarm Contacts

Remote alarm contact type

Isolated Form C

Switching capability Un/In

AC: 250V/0.5A     DC: 250V/0.1A; 125V/0.2A; 75V/0.5A

Cross-section of remote signaling wire (max)

1.5mm2(or # 16AWG)


TUV DT50, DS50.. Basic circuit diagram and Dimension.pdf