2 ports surge filter
-
25A Surge Filter
Prosurge surge filter DSF25 is used to protect single phase electrical distribution systems, especially to protect sensitive electronics against the harmful effects of transient surges. Features: Multi-stage protection circuit with LC Filter design to protect sensitive electronics. Provides extensive high frequency & RF filtering Application for 120~127V, 220~277V (L-N) TT/TN, or any 1-phase system with a grounded neutral Surge capacity 25kA 8/20us Rated Load current 25A, 16A is available Built in backup fuse for fault current protection DIN-Rail mounting LED failure indication & remote alarm function available Comply with UL1449 4th,IEEE C62.41, CSA C22.2,IEC/EN 61643-11
Email Details -
40 - 45A Surge Filter
Prosurge surge filter BSF50 is used to protect single phase electrical distribution systems, especially to protect sensitive electronics against the harmful effects of transient surges. Features: Multi-stage protection circuit with LC Filter design to protect sensitive electronics. Provides extensive high frequency & RF filtering Application for 120~127V, 220~277V (L-N) TT/TN, or any single phase system with a grounded neutral Protection capability 50 kA 8/20us Load current rating 45A, 20~32A is available All mode protection LED failure indication & remote alarm function available Comply with UL1449 4th,IEEE C62.41, CSA C22.2,IEC/EN 61643-11
Surge Protection with EMI - RFI filtering 40A surge filter single phase surge filter 25A Surge FilterEmail Details -
63A - 125A Surge Filter
Prosurge surge filter BSF100 is used to protect single/three phase electrical distribution systems, especially to protect sensitive electronics against the harmful effects of transient surges. Features: Multi-stage protection circuit with LC Filter design to protect sensitive electronics. Provides extensive high frequency & RF filtering Prosugre ESG+VTD technology to improve voltage clamping performance Application for 120~127V, 220~277V (L-N) TT/TN, or single phase system with a grounded neutral Application for 120/208 ~127/220 Vac, 220/380 to 277/480 Vac TT/TN, any 3-phase system with a grounded neutral Protection capability 25kA 10/350us or 100kA 8/20us per mode Surge capacity of N-PE mode up to 100kA 10/350 μs Load current rating 63A~125A available Built-in in series fuse for overload /short circuit protection available All mode protection,1+1 protection circuit for TN-S and TT systems LED failure indication & remote alarm function available and surge counter optional Comply with UL1449 4th,IEEE C62.41, CSA C22.2,IEC/EN 61643-11
Email Details